For inductively loaded DC circuits e.g for magnets, spark extinguishers have to be provided |
|
|
|
|
說明 |
|
TECHNICAL DATES
Pressure setting range |
1-10 bar |
Working pressure max. |
10 bar |
Bursting pressure |
20 bar |
Design |
Spring safety membrances |
Diaphragm |
NBR, special design VITON, CR, EPDM, KALREZ |
Manner of fastening |
Male thread |
Fitting thread YAY |
G 1/8", other thread types on demand |
Mounting position |
Any |
Ambient temperature |
-25℃ bis+85℃, higher temperatures on demand |
Medium |
Air, others on demand |
Adjustability |
Under pressure |
Switch back difference |
10%-15% |
Mechanical life |
106 |
Material |
Brass, special design VA, galvanized steel |
Weight |
26 gr |
Switching element |
Siver-plated contacts/special gold-plated contacts |
Reference voltage |
42V |
Reference frequency |
Not over 100 Hz |
Switching frequency max. |
200/min |
Maximum load |
2A |
Eloctrical connection |
Screw connection M2 |
Protective system |
IP00 |
Breaking capacity |
100VA |
|
|
|
|