For inductively loaded DC circuits e.g for magnets, spark extinguishers have to be provided |
|
|
|
|
|
說明 |
 |
TECHNICAL DATES
|
Pressure setting range |
1-10 bar |
|
Working pressure max. |
10 bar |
|
Bursting pressure |
20 bar |
|
Design |
Spring safety membrances |
|
Diaphragm |
NBR, special design VITON, CR, EPDM, KALREZ |
|
Manner of fastening |
Male thread |
|
Fitting thread YAY |
G 1/8", other thread types on demand |
|
Mounting position |
Any |
|
Ambient temperature |
-25℃ bis+85℃, higher temperatures on demand |
|
Medium |
Air, others on demand |
|
Adjustability |
Under pressure |
|
Switch back difference |
10%-15% |
|
Mechanical life |
106 |
|
Material |
Brass, special design VA, galvanized steel |
|
Weight |
26 gr |
|
Switching element |
Siver-plated contacts/special gold-plated contacts |
|
Reference voltage |
42V |
|
Reference frequency |
Not over 100 Hz |
|
Switching frequency max. |
200/min |
|
Maximum load |
2A |
|
Eloctrical connection |
Screw connection M2 |
|
Protective system |
IP00 |
|
Breaking capacity |
100VA |
|
|
 |
|